Technical Solutions Album · section 3

Installing floor panels at level 0.000

1. Table of maximum spans for SIP floors

Maximum span, mmJoist spacing, mmJoist section, mmLoad, kg/m²Floor thickness, mm
210062074 × 97250124
1700125074 × 97250124
330062074 × 147250174
2650125074 × 147250174
450062074 × 197250224
3500125074 × 197250224

When using the floors of the House, follow these requirements: without a specially developed design agreed with our company: do not make openings in the floors; do not route services through the floors; do not break the vapor barrier and waterproofing membranes in floors above a technical crawl space, a cold basement or under a cold attic; do not allow the floor insulation to get wet or over-moistened; do not damage the waterproofing on balconies, terraces and in bathrooms, including where the waterproofing meets door frames, walls and partitions.

Failure to comply with the listed requirements may lead to reduced load-bearing capacity of the floors, loss of sound insulation properties and rainwater leaks.

2. SIP floor on a timber grillage

Diagram 34.gifDiagram 35.gif

joists for 224 mm panels are built up from two boards 37 × 197 mm with screws 4,2 × 64 mm in a staggered pattern at a spacing of 250 mm.

3. SIP floor on a reinforced concrete foundation

Diagram 36.gifDiagram 37.gif

joists for 224 mm panels are built up from two boards 37 × 97 mm with screws 4,2 × 64 mm in a staggered pattern at a spacing of 250 mm.

4. SIP panel floor on a timber grillage with channel strapping of the piles

Diagram 38.gif

5. SIP floor on a support board with channel strapping of the piles

Diagram 39.gifDiagram 40.gif

joists for 224 mm panels are built up from two boards 37 × 197 mm with screws 4,2 × 64 mm in a staggered pattern at a spacing of 250 mm.

6. SIP floor with I-joists on a timber grillage

Diagram 41.gifDiagram 42.gif

7. SIP floor with I-joists on a reinforced concrete foundation

Diagram 43.gifDiagram 44.gif

the maximum span for SIP floors with I-joists is 4000 mm.

SIP floor with I-joists

Diagram 45.gifDiagram 46.gifDiagram 47.gif
  1. Detail 1
  2. Detail 2 (apply around the whole perimeter of the external walls at every second joist)
  3. Note: apply at every second joist on axes А and В, and in every tongue-and-groove joint on axes 1 and 4. Make the recess for the reinforcement on site.
  4. Detail 3
  5. Detail 4