Technology — Construction standards
|
House construction standard for “SIPwall” (SIP) technology
|
Existing violations and technological errors that occur when building houses with SIP technology |
Consequences of violating the technology |
|
Intermediate floors (level +0.000) and (level +2.800)
|
||
|
Reinforced SIP panels 224 mm thick. SIP panels 174 mm thick may be installed. Beam floor. |
Installing unreinforced panels with an embedded timber spacing of 1250 mm. Installing panels with OSB3 thinner than 12 mm Using floor panels thinner than 174 mm |
Sagging of the ceiling in the middle of the panels during use. Reduced floor rigidity, which can lead to collapse of the structure during use Reduction of the permissible load per 1 m2 |
|
Exterior walls
|
||
|
HOUSE walls use SIP panels 174 mm thick. DACHA (summer house) walls use SIP panels 124 mm thick. Embedded timber: glulam with a cross-section of at least 74x147 mm. Standard ceiling height is 2,8 m and 2,5 m. |
Installing panels with OSB3 thinner than 12 mm Using boards with a cross-section smaller than 74x150 mm as embedded timber
|
Reduced wall rigidity, which can lead to collapse of the structure during use Reduction of the permissible load per 1 m2 |
|
Roofing
|
||
|
Reinforced SIP panels 224 mm thick. SIP panels 174 mm thick may be installed. Cold rafter system |
Installing unreinforced panels with an embedded timber spacing of 1250 mm. Installing panels with OSB3 thinner than 12 mm Using floor panels thinner than 174 mm |
Sagging of the ceiling in the middle of the panels during use. Reduced floor rigidity, which can lead to collapse of the structure during use Reduction of the permissible load per 1 m2 |
|
Material requirements
|
||
|
Use of OSB-3 from European and Russian manufacturers for exterior SIP panels |
Use of Canadian OSB-3 for exterior SIP panels |
Lower moisture absorption values. |
|
Use of EPS foam, grade PPS-14 |
Use of EPS foam, grades PPS-13, PPS-12 |
Reduced load-bearing capacity of the SIP panels. |
|
Use of dry, planed timber treated with a fire and bio-protective compound |
Use of unplaned, green or “semi-dried” timber |
Formation of fungus, |
|
Use of special Spax screws to ensure the required rigidity of the structure |
Use of nails or lag screws (threaded self-tapping screws) |
Reduced rigidity of the structure, which can lead to deformation and collapse of the house. |